Marstair Cellarator CX(E) Indoor Unit
The innovative CX(E) Cellarator split system is designed to help the licensed trade maintain a cooled environment more effectively than ever before.
With its revolutionary one-piece moulded body, impregnated with an anti-bacterial additive, the CX(E) is ideal for cellar cooling, food preparation areas and any areas requiring controlled temperatures down to 4°C.
The Cellarator provides consistent temperature control with economy, ease of maintenance, flexible positioning, hygiene, safety and reliability.
- Capacity range from 2.3 - 6.8kW
- Long pipe runs up to 80m (50m for CKC/DCU+ 20)
- The unit controls temperatures down to 4°C (dependent upon system match)
- De-ice stat is standard on CXE electronic units
- An antibacterial agent is added to the chassis during the moulding process for complete mould protection throughout the material
- 6 fins-per-inch brewery specification heat exchanger
- Mounting brackets suitable for both wall and ceiling mounting and a waterproof power switch
- Direct access to the electrics at the front of the unit
- ABS drain tray incorporating standard 22mm OD fitting drain stub
- Easy to install electric heater kit with factory fit option
- Outdoor condensing units incorporating a low-pressure switch, HP switch and low ambient start as standard
- Optional ducted condensing units for where external installations are not feasible
- Stylish design chassis and rounded corners for safety
If the following capacities aren't sufficient for your project we also offer
multi-split systems with capacities up to a nominal 14 kW.
APPROXIMATE GUIDE TO CELLAR SIZING IN m3 @ 27°C AMBIENT
| ABOVE GROUND | BELOW GROUND |
---|
Model | 8°C | 12.7°C | 8°C | 12.7°C |
---|
CX(E) 30 + CKC 20 | 22m3 | 31m3 | 36m3 | 52m3 |
CX(E) 40 + CKC 30 | 27m3 | 39m3 | 45m3 | 64m3 |
CX(E) 50 + CKC 50 | 42m3 | 60m3 | 69m3 | 98m3 |
CX(E) 70 + CKC 80 | 70m3 | 100m3 | 111m3 | 158m3 |
GUIDE TO COOLING DUTY @ 8°C and 12.7°C/27°C AMBIENT
| CELLAR 8°C | CELLAR 12.7°C | CONNECTIONS |
---|
Model | TD (kW) | SD (kW) | SHR | TD (kW) | SD (kW) | SHR | SUCTION | LIQUID |
CX(E) 30 + CKC 20 | 2.27 | 1.70 | 0.75 | 2.80 | 2.10 | 0.75 | 1/2" | 3/8" |
CX(E) 40 + CKC 30 | 2.67 | 1.82 | 0.68 | 3.30 | 2.24 | 0.68 | 1/2" | 3/8" |
CX(E) 50 + CKC 50 | 3.73 | 2.46 | 0.66 | 4.60 | 3.02 | 0.66 | 1/2" | 3/8" |
CX(E) 70 + CKC 80 | 5.51 | 3.47 | 0.63 | 6.80 | 4.30 | 0.63 | 5/8" | 1/2" |
GUIDE TO CXE LOW-TEMPERATURE CAPACITIES @ 4°C/27°C AMBIENT
| CELLAR 4°C | CONNECTIONS |
---|
Model | TD (kW) | SD (kW) | SHR | SUCTION | LIQUID |
CXE 40 + CKC 20 | 2.30 | 2.00 | 0.85 | 1/2" | 3/8" |
CXE 50 + CKC 40 | 3.50 | 2.80 | 0.80 | 1/2" | 3/8" |
CXE 70 + CKC 60 | 5.00 | 3.50 | 0.70 | 5/8" | 3/8" |